Wire size for 200 amp service copper - Aug 23, 2023 · The size of the conduit needed for a 200-amp service will depend on the length of the wire run. Generally, you should use 3/4 inch or 1 inch conduit for up to 100 feet and one 1 1/4 inch or larger for longer runs. Always consult a professional electrician or check with your local permit office before beginning any electrical wiring project.

 
Jan 20, 2024 · Standard wire sizes for a 200-amp residential service could be as follows: 1. Copper Wire. 2/0 AWG (American Wire Gauge) copper is a standard size for a service entrance conductor (from the utility to the main distribution panel). You may need 3/0 or 4/0 AWG copper for the leading feeder conductors, which run from the main distribution panel to ... . Onslow bay buoy

1385. 1560. 960. 1150. 1335. 2000. Note: View additional wire size charts from the list below. Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (30°C) Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (40°C) Maximum Allowable Ampacities for Conductors in Free Air (40°C) For ambient …Usually, a 200 amp service entrance cable may be a triplex (3 wires) for single phase, or quadruplex (4 wires) for three-phase service. Thus, the cable must only …Within the last quarter, Southern Copper (NYSE:SCCO) has observed the following analyst ratings: Bullish Somewhat Bullish Indifferent Somewh... Within the last quarter, Southe...Key takeaways – According to the NEC, a 4-gauge copper wire is recommended, or possibly 2-gauge for distances over 200 feet, to ensure safety and efficiency. Therefore, when selecting the correct wire size for a 50 amp circuit over 200 feet, you must consider current carrying capacity, voltage drop, and distance. Let’s dive …Recycled copper crafts can be a lot of fun to make. Visit HowStuffWorks to learn all about making recycled copper crafts. Advertisement Making crafts by hand can be extremely rewar...October 9, 2023 by GEGCalculators. The size of the ground wire for an electrical circuit depends on the circuit’s amperage rating. Common ground wire sizes for copper conductors include 10 AWG for 20-50A circuits, 8 AWG for 60-100A circuits, and 6-4 AWG for larger circuits. Always follow local electrical codes and consult a professional for ...The size of wire required for a 200 amp service panel is 4/0 AWG. This is also sometimes referred to as “4 gauge” wire. This wire size will be able to handle up to 200 amps of power before it needs to be replaced. Be sure to use copper or aluminum wire that is rated for outdoor use when running the wire from the main power source to the panel.If copper is the go-to metal in a clean energy world, then why is its price stagnant, asks commodity writer Maleeha Bengali, who says perhaps it's because demand at present, es...Jun 11, 2020. #6. david luchini said: 3/0. (2/0 can't be protected at 200A.) My thought was that since the generator would not be supplying 100% of the loads in the house that the rating could be adjusted by the 83% of service rating per 310.15 (b) (7). F.Minimum Requirements For 200 Amp. AWG or American Wire Gauge is the standard for sizing electrical wiring. A 200 amp service requires either #2/0 AWG copper wire or #4/0 AWG aluminum or copper-clad aluminum wire. These are the safest wires to use as they permit the use of full amperage of the electrical service without too high a voltage drop.For a 200 amp service, the most commonly recommended size for copper wire is 3/0 AWG. This gauge ensures safe and efficient electrical distribution. Always adhere to local electrical codes and consult with an electrician. Copper Wire for 200 Amp Service Size ChartThe calculation stands like this: 30 amp wire = 30A x 100% / 80% = 37.5A ampacity. So, with 37.5A ampacity, an 8 AWG wire after 10 AWG wire will perfectly fit 30 amps. The 310-16 code suggests adding an extra 20% of the wire’s ampacity for 30 amps every time the distance increases to 100 feet.Jan 15, 2024 · The ordinary code of wire to use for a 200 amps service panel is #2/0 copper wire that needs to have a conduit of 2 inches. The electric code of your country may also set the bar for utmost safety. For aluminum or copper-clad wire, there shall be a wire with a gauge of #4/0 AWG. The MCM rating would be 211.60 kcmil. For 60-amp electrical service, 6-gauge copper or aluminum wire is the correct size to power such devices as electric furnaces and large electric heaters. A 50-amp circuit breaker o...Oct 1, 2023 · 200 amp x 100% / 80% = 250 amps (to account for the 80% rule) Next, determine how long your wire run is. Add 20% for 100 feet and 10% for 50 feet. So, if your run is 150 feet, you’ll need to increase the amperage of the wire by 30%. Hence: 250 amps x 1.3 = 325 amps. The conduit size should be able to carry 325 amps. Attach white electrical tape to both ends of one 2/0 AWG THHN wire. Insert this wire, two more 2/0 AWG THHN wires and one #4 bare copper wire into the meter base. Pass it through the attached conduit until it reaches and exits the electrical panel inside the home. Leave enough wire on both ends to attach to the appropriate wire lugs.The size of the ground wire you need for a 200 amp service will depend on several factors, including the length of the wire run, the type of wire you are using, and the specific requirements of your local building code. In general, a 200 amp service will require a ground wire that is at least 2/0 copper or 4/0 aluminum or copper-clad aluminum ...I’m planning on upgrading my electrical service to 200 amps but I’m not sure what aluminum wire size I need. I get confused with the ambient temperature chart, I’m located around Houston Texas area. ... The 200 amp service can be derated to .83 so that's 166 amps. At 75 degrees C, 3/0 Al is 155 amps and 4/0 Al is good for 180 amps so …The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Search Amazon for your Electrical ...May 5, 2024 · The size of wire required for a 200 amp service panel is 4/0 AWG. This is also sometimes referred to as “4 gauge” wire. This wire size will be able to handle up to 200 amps of power before it needs to be replaced. Be sure to use copper or aluminum wire that is rated for outdoor use when running the wire from the main power source to the panel. The size of the ground wire for a 200-amp service depends on various factors, including local electrical codes and specific installation conditions. However, as a general guideline, a copper grounding conductor of 4/0 AWG (American Wire Gauge) or an aluminum conductor of 250 kcal is often recommended.In this case, the Amp Service Wire Size must be at least a 2/0 AWG of copper wire when installing a 200-amp panel. It’d help if you wired larger than a 4/0 AWG when using copper-clad or aluminum. Before determining if the 200 amps wire is best for you, think about a few things.The center, which is a division of the National Weather Service, observed conditions of an extreme geomagnetic storm at 6:54 p.m. ET on Friday evening, reaching …Jan 20, 2024 · Standard wire sizes for a 200-amp residential service could be as follows: 1. Copper Wire. 2/0 AWG (American Wire Gauge) copper is a standard size for a service entrance conductor (from the utility to the main distribution panel). You may need 3/0 or 4/0 AWG copper for the leading feeder conductors, which run from the main distribution panel to ... How many breakers in a 200 amp panel; Wire size for 40 amps; Conclusion. To use a 200 amp service, you need #2/0 copper or #4/0 aluminum wiring. Contact an electrician for more information. Making sure you have the right wire size will ensure that your electrical equipment operates properly and does not cause a dangerous situation.Min. Wire Ampacity (100 ft away) = 125A × 1.2 = 150 Amps. That means that we need a wire with at least 150 ampacity to deliver 100 amp service 100 feet away. If you check the wire size chart (you have the link in the introduction), the #0 AWG wire (also known as 1/0 AWG wire) has 150 ampacity. That means that #0 AWG wire is the perfect size ...When it comes to electrical installations and appliances, safety should always be the top priority. One critical aspect of ensuring safety is choosing the right wire size for the a...For a 100 amp service, many electricians opt for wire size #2 or #1 AWG aluminum or copper-clad wiring. This is because aluminum conducts electricity slightly differently than copper. I know it can be a bit confusing, but the main takeaway for aluminum wire size is generally to go a size up (meaning a lower number on the gauge) compared to copper.The size of the wire you need for a 200 amp service will depend on the length of the run and the gauge of the wire. The most common wire gauges used for a 200 amp service are 4/0 and 2/0. The 4/0 wire is the thicker of the two and is typically used for long runs, while the 2/0 wire is thinner and typically used for shorter runs.The correct wire size for different amp services depends on the specific application and the National Electrical Code’s guidelines. For example, a 100-amp service requires a minimum wire size of #2 copper or #1/0 aluminum, while a 200-amp service requires a minimum wire size of #2/0 copper or #4/0 aluminum.February 13, 2024 by Ekram Hossain. For a 200 amp electrical service, a 2/0 AWG copper wire or 4/0 AWG aluminum or copper-clad aluminum wire is needed. This choice meets …Oct 1, 2023 · When looking for a 200 amp service entrance wire size, you should consider the 3% allowable voltage drop by NEC standards. As a result, you need to use a much bigger wire size than the one for short-distance setups. In this case, instead of using a 2/0 copper wire, you should use 300 kcmil copper with only a 2.78% voltage drop. What Size Grounding Wire is Required for a 200 Amp Service? A grounding wire ranging from 2AWG to 8 AWG is recommended for a 200-amp service. You can use 8AWG (Copper) or 6 AWG (Aluminum) grounding wires for a 200-amp service. You can also use copper conductors of 4AWG and aluminum conductors of 2AWG.300ft from disconnect to panel. 200 amps. My calculations show 350 mcm Al for 3.46% vd. The client has a buddy that is a master electrician and is telling him to run 250/250/ (4/0). I'm suggesting 350/350/350 as it's a long run and I don't think derating the nuteral is worth the few bucks of cost saving. The Wire Size Calculator below will calculate the proper wire size for a circuit based on circuit amps, preferred (or available) wire insulation, conductor type and installation specifications. For more advanced considerations, use the Wire Size Calculator or the Advanced Wire Size Calculator. The size of the ground wire for a 200-amp service depends on various factors, including local electrical codes and specific installation conditions. However, as a general guideline, a copper grounding conductor of 4/0 AWG (American Wire Gauge) or an aluminum conductor of 250 kcal is often recommended.Do you know how to tarnish copper? Find out how to tarnish copper in this article from HowStuffWorks. Advertisement Whether it's a family heirloom, a rare coin, or handmade -- or s...Size Wire for 100 Amp Service. AWG, American Wire Gauge, is the US standard for sizing electrical wiring. A 100 amp breaker panel requires either #4 copper wiring or #2 aluminum or copper-clad wiring. Which wire used is determined by the voltage drop and length of the wiring. The following table reflects wiring size, length, and voltage …The calculator is designed to accept the total line voltage and current of the combined three cables. The equation for the area of a single wire is modified to: A = \frac {\sqrt 3 I \varrho L} {V} A =V 3 I ϱL. The factor of \sqrt 3 3 is needed to convert between the system's phase current and line current. The factor of 2 disappears, as there ...For a 100 amp sub panel, a minimum wire size of #3 AWG copper is recommended. This wire size can handle the current load without significant voltage drop. 2. Aluminum Wire: Aluminum wire is an alternative to copper wire and is often used in larger electrical applications. For a 100 amp sub panel, a minimum wire size of #1/0 AWG aluminum is ...We used the formula: Power = Phase current × Phase voltage × Power factor. Try the Omnicalculator 100 amps wire size tool to get the proper wire you should install. Arturo Barrantes. The 100-ampere wire size calculator will assist you in choosing the proper wire size for your next equipment installation.8 gauge AWG copper wire has an ampacity of 50A; this is the wire size you need for an 8,000-watt generator. Example For Generator Amps: This is easier. Let’s say you have a 50 amp generator. What size wire do you need for a 50 amp generator? You have to multiply the amps by a 1.25 factor (80% NEC rule) like this: 50A×1.25 = 62.5A.This wire size is one of the favorites for large-amp needs. It is the perfect 200 amp wire size with 200 ampacity (3/0 copper wire ampacity has 200A ampacity) at 75°C. It also has a very high 2.7 kA Preece fusing current (power factor is already factored in). Most 3/0 gauge wires with 85.00 mm2 cross-section are rated up to 600 volts.As a result, upgrading to a 200 amp service is fairly frequent. But, the tricky part of this is selecting the right length of wiring. What is the 200 amp wire size? You’ll need to get a #2/0 copper wire, #4/0 aluminum wire, or copper-clad aluminum wire to begin. Copper wires have high conductivity and are heat and corrosion-resistant.Get free shipping on qualified 200 Service Entrance Wires products or Buy Online Pick Up in Store today in the Electrical Department. ... Total Wire Length (ft.) 250 ...The best size of wire for 150 amp is 1 AWG copper or 2 AWG aluminum or copper-clad aluminum. If the temperature is around 194°F, use a 3 AWG aluminum wire gauge. The size of the wire should be around 1-1/4th inch wide. The right size for hot and neutral wires is 1 AWG copper or 2 AWG aluminum. For the ground wires, it is 6 AWG …Copper gutter guards are a worthy investment, but how do you decide on the best ones? Our guide breaks down the best copper gutter guards to choose from. Expert Advice On Improving...Each has a different ampacity for a specified gauge size, and these ampacities are found in NEC® Table 310.15(B)(16) for the calculations in this app. For example, 3/0 AWG copper has an ampacity of 200 amps at 75℃, while 3/0 AWG aluminum has an ampacity of 155 amps at 75℃. WIRE / CABLE TYPE:Application. Southwire® Type SE, Style SER service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatures not to ...The minimum wire size for a 100 amp sub-panel is 4 AWG copper or 2 AWG aluminum according to the 83% rule, which defines that the wire size can handle 83% of the amperage of the sub-panel. In these conditions, 83% of 100 amps is 83 amps, so the wire size can handle at least 83 amps.Two-inch conduits are used to hold the copper and aluminum wires for 200-amp electrical service. In addition, a #4 bare copper conductor is used for the connection between the ground rod/plate and the neutral connection block of the distribution panel for a 200-amp service. A 165- to 200-amp fuse is used on the service entrance wire at the … The Wire Size Calculator below will calculate the proper wire size for a circuit based on circuit amps, preferred (or available) wire insulation, conductor type and installation specifications. For more advanced considerations, use the Wire Size Calculator or the Advanced Wire Size Calculator. Jan 6, 2010 · Jan 6, 2010. #8. 200 amp commercial service i forgot to mention that i am coming from a meter/disco outside and hitting a panel about 50 ft away.Looking at table 310.16;for copper-4/0 and for aluminum 300's. Having the right wire size for your 200 amp service is crucial for safety and efficiency. In this section, we will discuss the recommended wire sizes for copper and aluminum wires, as well as how distance and voltage drop considerations play a role in your selection. Copper Wires: #2/0 AWG Copper. For 200 amp service using copper wires, it is ... Investor interest is on the rise and I have two price targets....ERO Ero Copper (ERO) is a copper producer with operations in Brazil and corporate headquarters in Vancouver, B.C. E...For a 100 amp service, many electricians opt for wire size #2 or #1 AWG aluminum or copper-clad wiring. This is because aluminum conducts electricity slightly differently than copper. I know it can be a bit confusing, but the main takeaway for aluminum wire size is generally to go a size up (meaning a lower number on the gauge) …Aug 23, 2023 · The size of the conduit needed for a 200-amp service will depend on the length of the wire run. Generally, you should use 3/4 inch or 1 inch conduit for up to 100 feet and one 1 1/4 inch or larger for longer runs. Always consult a professional electrician or check with your local permit office before beginning any electrical wiring project. 1-48 of 225 results for "200 amp wire" Results. Check each product page for other buying options. Nassau Electrical Supply 200' Monmouth 4/0-4/0-4/0 Aluminum URD Triplex Cable. ... 50 FT Ground Wire 4 AWG Gauge Solid Bare Copper 200A Service Cables Electronic Stranded Wire Cable Electrics DIY. 5.0 out of 5 stars. 1. $113.72 $ 113. 72. FREE ...If copper is the go-to metal in a clean energy world, then why is its price stagnant, asks commodity writer Maleeha Bengali, who says perhaps it's because demand at present, es...The calculator is designed to accept the total line voltage and current of the combined three cables. The equation for the area of a single wire is modified to: A = \frac {\sqrt 3 I \varrho L} {V} A =V 3 I ϱL. The factor of \sqrt 3 3 is needed to convert between the system's phase current and line current. The factor of 2 disappears, as there ...Occupation. Electrician. Jul 7, 2020. #3. 4/0 AL is good for 180 amps. 250 AL is good for 205 amps. If you can show your calculated load is less than 180 amps, you can legally go up to the next standard size, a 200 amp breaker. That's code minimum. Over here, we would use 250 AL in a 2.5-3" depending on which size we felt like using.Apr 27, 2023 · Allowable ampacity of 3/0 copper wire is 225 Amp, while the allowable ampacity of 4/0 aluminum wire is 205 Amp. 2/0 AWG copper wire is not completely out of the question, but its ampacity is 195 Amp-200 Amp, which will put it at a maximum load, so using 3/0 AWG copper is a better option. For grounding conductors, the minimum size for is 4 AWG ... BUT when running the service entry cable for a longer distance, like your 150 feet, it will be wire size 2/0 - copper or 4/0 aluminum. ... I have a 650' run from the service pole and I'm not sure with the voltage drop what size wire is needed for a 200 amp service. On 2019-07-29 by (mod) - 200 amp box and running 300 foot ...The minimum wire size that you can use for a 100-amp service is 4 gauge copper or 2 gauge aluminum. Wire Sizes Chart for 100 amp Service: Distance (Feet) Minimum Wire Size (Copper) Recommended Wire Sizes (Copper) Minimum Wire Size (Aluminum or Copper-Clad) Recommended Wire Sizes (Aluminum or Copper-Clad) Up …Current is measured in amperes (amps). Selecting the appropriate wire size for a circuit is crucial to prevent overheating, which can lead to damage and fire hazards. Devices and Amp Draw: The number and type of electrical devices connected to a circuit determine the ampacity requirement of the conductor. For example, a typical general-purpose ...As we will see in the NEC ampacity chart, copper wires can handle more amps than same-size aluminum wires. That’s because copper has a lower resistivity (1.72 × 10 -8 Ohm×m at 68°F) than aluminum (2.65 × 10 -8 Ohm×m at 68°F). That means that the conductivity of copper is higher than the conductivity of aluminum. Temperature.February 13, 2024 by Ekram Hossain. For a 200 amp electrical service, a 2/0 AWG copper wire or 4/0 AWG aluminum or copper-clad aluminum wire is needed. This choice meets …Inside a 3′′ conduit, a 200 amp electrical service requires #2/0 AWG copper wire or #4/0 AWG aluminum or copper-clad wire. A 200 amp electrical service is not a do …Within the last quarter, Southern Copper (NYSE:SCCO) has observed the following analyst ratings: Bullish Somewhat Bullish Indifferent Somewh... Within the last quarter, Southe...When looking for a 200 amp service entrance wire size, you should consider the 3% allowable voltage drop by NEC standards. As a result, you need to use a much bigger wire size than the one for short-distance setups. In this case, instead of using a 2/0 copper wire, you should use 300 kcmil copper with only a 2.78% voltage drop.If copper is the go-to metal in a clean energy world, then why is its price stagnant, asks commodity writer Maleeha Bengali, who says perhaps it's because demand at present, es...Feb 4, 2024 · Size Wire for 100 Amp Service. AWG, American Wire Gauge, is the US standard for sizing electrical wiring. A 100 amp breaker panel requires either #4 copper wiring or #2 aluminum or copper-clad wiring. Which wire used is determined by the voltage drop and length of the wiring. The following table reflects wiring size, length, and voltage drop: This DC wire size calculator will help you calculate the wire gauge automatically. Example: For 100 amp service, you will a wire with at least 125A ampacity. That means you will need a 1 AWG wire for 100 amps since it has 130A ampacity. Wire size chart. In this chart, you can find wire sizes for 1 amp, 10 amp, 20 amp, 30 amp, 40 amp, 50 amp, 60 ...Table Of Contents. 1 Wire Size for 200 Amp 350 Feet. 2 2/0 Copper Wire for 200 Amp Service. 3 100 Amp Vs. 200 Amp Wire Size. 4 200 Amp Wire Size Aluminum. 4.1 Aluminum Service Wire Pros. 4.2 …Single Family Residential Electrical Services | NFPAThe cost of wire for 200 amp service varies based on the home size, wire type. For a two-thousand square foot building, you will spend more than thousand-five hundred dollars. It is recommended to use copper-clad aluminum or copper wire if the residential place has the high load capacity.Each has a different ampacity for a specified gauge size, and these ampacities are found in NEC® Table 310.15(B)(16) for the calculations in this app. For example, 3/0 AWG copper has an ampacity of 200 amps at 75℃, while 3/0 AWG aluminum has an ampacity of 155 amps at 75℃. WIRE / CABLE TYPE:For a 200 amp service, the most commonly recommended size for copper wire is 3/0 AWG. This gauge ensures safe and efficient electrical distribution. Always adhere to local electrical codes and consult with an electrician. Copper Wire for 200 Amp Service Size ChartAug 2, 2008 · 250.66 is for the GEC not the neutral, however art. 250.24(C)(1) does reference that the grounded conductor not be smaller than the required GEC in Table 250.66. That being said unless you can calculate the neutral load and determine a #4 is satisfactory I would not do this. I generally downsize one wire size for the neutral. Doctor Copper is still a harbinger of global economic health -- keep a close eye on copper prices as the trade war marches on....ANFGF Have you ever wondered why copper earned the ...When looking for a 200 amp service entrance wire size, you should consider the 3% allowable voltage drop by NEC standards. As a result, you need to use a much bigger wire size than the one for short-distance setups. In this case, instead of using a 2/0 copper wire, you should use 300 kcmil copper with only a 2.78% voltage drop.Can someone show where it says in the NEC that you can use a #6 bare copper ground wire to both ground rods. There is a argument that you must use a #4 bare copper minimum to both ground rods for a 200 amp service. C3PO Senior Member. Location Tennessee. Jun 10, 2008 #2 Look at Section 250.66(A) wbalsam1 Senior …

Advanced Wire Size Calculator. Enter the information below to calculate the appropriate wire size. Voltage - Enter the voltage at the source of the circuit. Single-phase voltages are usually 115V or 120V, while three-phase voltages are typically 208V, 230V or 480V. Amperes - Enter the maximum current in amps that will flow through the circuit.. Joann fabrics pensacola

wire size for 200 amp service copper

A 50 amp sub panel will require at least 3 to 6 AWG wires. Here, I considered the distance around 55 feet. If the distance is longer, I suggest you use thicker and lower gauge wires. If the sub-panel distance from the main panel is 150 or 200 feet, you can use 4 AWG copper or 3 AWG aluminum or copper-clad wires.The size of the wire you need for a 200 amp service will depend on the length of the run and the gauge of the wire. The most common wire gauges used for a 200 amp service are 4/0 and 2/0. The 4/0 wire is the thicker of the two and is typically used for long runs, while the 2/0 wire is thinner and typically used for shorter runs.Within the last quarter, Southern Copper (NYSE:SCCO) has observed the following analyst ratings: Bullish Somewhat Bullish Indifferent Somewh... Within the last quarter, Southe...If you apply the NEC 80% rule, 250 kcmil wire can handle up to 204 amps. That’s why it is considered a 200 amp wire. Basically, we are trying to answer what ground wire do you need for 200 amp service. If you consult the copper ground wire size chart above, you can see that you will need a 2 AWG copper ground wire to adequately ground a 250 ...Enter the information below to calculate the appropriate wire size. Voltage - Enter the voltage at the source of the circuit. Single-phase voltages are usually 115V or 120V, while three-phase voltages are typically 208V, 230V or 480V. Amperes - Enter the maximum current in amps that will flow through the circuit.The wire size needed for a 200-amp service depends on the distance between the power source and the main electrical panel, with copper wiring typically …3/0,3/0,3/0 & 1/0 Copper SER Service Entrance Cable. Sold by the foot cut to length. ... 200°C; PTFE Wire - 200C; TGGT Wire - 250°C; MG Wire - 450°C/550°C; Medium Voltage Cable. ... Service Entrance Cable: Wire Size: 3/0 AWG # of Conductors: 3 Conductors w/ Ground: Conductor Material: Bare Copper: Stranded or Solid: Stranded:Wire Size for 100-Amp Service. Most 100-amp service panels require #2 AWG wire. Electricians use these wires when there’s significant space between the circuit breaker panel and electrical equipment (such as air conditioners), which is common in large commercial buildings. You’ll need to use #4 AWG wire if the distance between the …For underground 200 amp service, the wire should be 2/0 AWG. The size of the wire you require will vary according to the voltage and amperage of the service. Generally, the aluminum wire should be 4/0 AWG. Steel armored wire of #2 AWG or greater should be fitted to a 200 amp underground utility box.Depending on the wire type, the best size for a 200 amp service is a 2 AWG copper wire or a 4 AWG aluminum or copper-clad aluminum wire. The size of the wires should be the same as the live and neutral wires.200 Amp Wire = 200A × 100% / 80% = 250A Ampacity. That means that you can to use a wire that has an ampacity of 250A or higher in order to set up a 200 amp circuit. As you …Jun 14, 2023 · The best size of wire for 150 amp is 1 AWG copper or 2 AWG aluminum or copper-clad aluminum. If the temperature is around 194°F, use a 3 AWG aluminum wire gauge. The size of the wire should be around 1-1/4th inch wide. The right size for hot and neutral wires is 1 AWG copper or 2 AWG aluminum. For the ground wires, it is 6 AWG copper or 4 AWG ... So take the "kcmil" size of the hot wire you choose, divide by 2.52, and choose a ground wire with that kcmil or larger. (this works out the same aluminum or copper). This will probably be down in the AWG sizes, so you need a kcmil to AWG chart: 1 AWG = 84 kcmil; 1/0 AWG = 106 kcmil; 2/0 AWG = 133 kcmil; 3/0 AWG = 168 kcmil; 4/0 ….